Goodman Furnace 2 (red LED) error code

The control board's pressure-sensing input reads pressure at a moment when there should be none — the pressure sensor is stuck in the closed position or its wiring is shorted.

Also shown as: 2 red flashes, two red flashes, red LED flashing twice, fault code 2 red

Last updated: September 30, 2026

Quick answer: Goodman furnace error code 2 (red LED): pressure sensor stuck closed — reading pressure when it should read zero. The most common cause is pressure sensor contacts stuck closed. Try this first — power-cycle once. If that does not clear it, check the sensor hoses.

What causes the 2 (red LED) error?

  • Pressure sensor contacts stuck closed
  • Shorted or pinched sensor wiring
  • Failed pressure sensor

How to fix Goodman 2 (red LED) — step by step

Work through these in order, from simplest and safest first. Stop as soon as the code clears.

  1. Power-cycle once
    Turn the furnace off at the service switch, wait 30 seconds, and turn it back on. If the code clears and heat works, the sensor may have stuck temporarily.
  2. Check the sensor hoses
    With power off, look at the small rubber hoses running to the pressure sensor for kinks, cracks, or trapped water, and straighten or drain them if needed.
  3. Call a technician for testing
    The sensor must be tested with a meter and replaced if it will not open. Wiring shorts also need professional repair.
    Safety warning: Do not bypass or jumper the pressure switch — it is a safety device that proves the venting system is working.

When to call a technician

Stop and call a qualified technician if any of these apply:
  • The code returns after a power cycle
  • The sensor hoses look fine but the fault persists

Frequently asked questions

What does the pressure sensor do?

It proves the inducer fan is moving combustion air through the furnace and venting exhaust outside. If the control cannot trust that reading, it will not let the burners fire.

Can I just disconnect the sensor?

No. Bypassing a pressure switch defeats a critical safety check and can let the furnace run with blocked venting — a carbon monoxide risk.